A new method for manual measurements of inhibition zones with the Bauer-Kirby disk susceptibility test

Authors

Keywords:

Bauer-Kirby, disk-diffusion test, inhibition zone

Abstract

Microbiologists often measure the diameter of inhibition zone of the antimicrobial activity over microorganisms by the disk-diffusion method of Bauer-Kirby. Usually, the measurement process is not accurate enough and it is often done visually with a ruler. More accurate measurements can be done when using photographs; however, when the photographs are taken by non-professionals (students), they are often made with non-optimal (not perpendicular) viewing angle and sometimes the scaling object is missing in the pictures. The paper presents a design and software supplementation of a method for measurement of inhibition zone using non-optimal photographs. The computer program can be used for distance learning, verification of results, recovery of lost results and/or more accurate measurements.

Author Biographies

Milena Petrova, Faculty of Biology, Sofia University

Milena Nikolova Petrova
Faculty of Biology
Sofia University “St. Kliment Ohridski”
e-mail: milena petrova@biofac.uni-sofia.bg

Philip Petrov, Faculty of Mathematics and Infromatics, Sofia University

e-mail: philip@abv.bg

References

D. Atsamniaa, M. Hamadachea, S. Haninia, O. Benkortbia, D. Oukrif. Prediction of the Antibacterial Activity of Garlic Extract on E. coli, S. aureus and B. subtilis by Determining the Diameter of the Inhibition Zones Using Artificial Neural Networks. LWT - Food Science and Technology, 82 (2017), 287–295, doi: 10.1016/j.lwt.2017.04.053.

A. W. Bauer, W. M. M. Kirby, J. C. Sherris, M. Turck. Antibiotic Susceptibility Testing by a Standardized Single Disk Method. Am. J. Clin. Pathol., 45 (1966), 439–496.

T. J. Collins. ImageJ for Microscopy. Biotechniques, 43, No S1 (2007), S25–S30.

A. Gavoillep, B. Bardy, A. Andremont. Measurement of Inhibition Zone Diameter in Disk Susceptibility Tests by Computerized Image Analysis. Computers in Biology and Medicine, 24, No 3 (1994), 179–188, doi: 10.1016/0010-4825(94)90014-0.

M. Hombach, R. Zbinden, E. Bottger. ¨ Standardisation of Disk Diffusion Results for Antibiotic Susceptibility Testing Using the Sirscan Automated Zone Reader. BMC Microbiol. 13 (2013), Article No 225, doi: 10.1186/1471-2180-13-225

W. R. Knorr. When Circles Don’t Look Like Circles: An Optical Theorem in Euclid and Pappus. Arch. Hist. Exact Sci., 44 (1992), 287–329, https://doi.org/10.1007/BF00374758.

C. T. Rueden, J. Schindelin, M. C. Hiner, B. E. DeZonia, A. E. Walter, E. T. Arena, K. W. Eliceiri. ImageJ2: ImageJ for the Next Generation of Scientific Image Data. BMC Bioinformatics, 18 (2017), Article No 529, doi: 10.1186/s12859-017-1934-z.

Downloads

Published

2021-04-01

How to Cite

[1]
Petrova, M. and Petrov, P. 2021. A new method for manual measurements of inhibition zones with the Bauer-Kirby disk susceptibility test. Mathematics and Education in Mathematics. 50, (Apr. 2021), 185–190.

Issue

Section

Section B: Mathematical Modelling and Informatics